Specs
DOWNLOAD BROCHURE
- Operating Environment: 0° F to 105º F, 10 to 95% Relative Humidity (indoor use only)
- MicroZone Power Modulator input power: 90 – 130V, 50/60 HZ
- MicroZone Power Modulator load rating: 16A maximum (1,920 Watts @ 120VAC)
- MicroZone Power Modulator load types: Incandescent heating lamp and/or resistive heating pad
- Temperature sensing probe error: Less than 2º F
- Electrical protection: Short circuit, overload and voltage surge
- Noise filter: FM radio filter
- Enclosures: Weather tight (approximately 4″ x 4″ x 2″)
- Internal Protection: The control is protected against transient voltage spikes, thermal overload and short circuits in heating devices.